Port Monitor
The SiteScope Port Monitor verifies that a connection can be made to a
network port and measures the length of time it takes to make the
connection. Optionally, it can look for a string of text to be returned or
send a string of text once the connection is made.
Each time the Port Monitor runs, it returns a status message and writes them in the monitoring log file. It
also writes the total time it takes to receive a response from the remote
service.
Usage Guidelines
The Port Monitor is useful for monitoring network applications that none
of the other SiteScope monitors watch. You will be notified immediately if
SiteScope is unable to connect to the monitored port.
What to monitor
You can use the Port Monitor to watch those network applications
that SiteScope does not specifically watch, such as Gopher and IRC
services, some media services, or other custom network applications.
About scheduling this monitor
Scheduling Port monitors depends on the application or system you are monitoring.
The Port Monitor does not use many resources, so you can schedule it to run as often
as every 15 seconds if necessary. Monitoring most systems every 10 minutes
is normally sufficient.
Status
The reading is the current value of the monitor. The possible values for
the Port Monitor are:
- OK
- unknown host name
- unable to reach server
- unable to connect to server
- timed out reading
- match error
The status is logged as either good or error. An error status is
returned if the current value of the monitor is anything other than OK.
Completing the Port Monitor Form
To display the Port Monitor Form, either click the Edit link for
an existing Port Monitor listed in a monitor table, or click the add a
Monitor link on a group's detail page and click the
Add Port Monitor link.
Complete the items on the Port Monitor form as follows. When the
required items are complete, click the Add Monitor button.
- Host Name
-
Enter the IP address or the name of the host that you want to
monitor. For example, you could enter either 206.168.191.21 or
demo.thiscompany.com.
- Port Number
-
Choose the port number to connect to from the list of services, or
enter a port number in the text box. Additional entries can be
added to list by editing the master.config file in the
<SiteScope install path>/SiteScope/groups
directory.
- Update every
-
Select how often the monitor should try to reach the host.
The default interval is to run or update the monitor once every 10 minutes.
Use the drop-down list to the right of the text box to specify another update
interval in increments of seconds, minutes, hours, or days. The update interval
must be 15 seconds or longer.
- Title
-
Enter a title text for this monitor. This text is displayed in the
group detail page, in report titles, and other places in the SiteScope
interface. If you do not enter a title text, SiteScope will
create a title based on the host, server, or URL being monitored.
Advanced Options
The Advanced Options section presents a number of ways to customize
monitor behavior and display. Use this section to customize error and warning
thresholds, disable the monitor, set monitor-to-monitor dependencies, customize
display options, and enter other monitor specific settings required for
special infrastructure environments. The options for this monitor type are
described below. Complete the entries as needed and click the Add
or Update button to save the settings.
- Disable
-
Check this box to temporarily disable this monitor and any
associated alerts. To enable the monitor again, clear the box.
- Send String
-
This advanced option gives you the ability to customize the string
sent after a connection is made.
- Match String
-
This advanced option gives you the ability to check for a string of
text after a connection is made. If the text is not received, the
monitor will display "no match on content". The search is
case sensitive.
- Timeout
-
The number of seconds that the Port monitor should wait for the
connection to the port, and for any sending and receiving to
complete. Once this time period passes, the Port monitor will log
an error and report an error status.
- Verify Error
-
Check this box if you want SiteScope to automatically run this
monitor again if it detects an error. When an error is detected,
the monitor will immediately be scheduled to run again once.
Note: In order to change the run frequency of this
monitor when an error is detected, use the Update every (on
errors) option below.
Note: The status returned by the Verify Error run
of the monitor will replace the status of the originally scheduled
run that detected an error. This may cause the loss of important
performance data if the data from the verify run is different than
the initial error status.
Warning: Use of this option across many monitor instances
may result in significant monitoring delays in the case that
multiple monitors are rescheduled to verify errors at the same
time.
- Update Every (on error)
-
You use this option to set a new monitoring interval for
monitors that have registered an error condition. For example, you
may want SiteScope to monitor this item every 10 minutes normally,
but as often as every 2 minutes if an error has been detected. Note
that this increased scheduling will also affect the number of
alerts generated by this monitor.
- Schedule
-
By default, SiteScope monitors are enabled every day of the
week. You may, however, schedule your monitors to run only on
certain days or on a fixed schedule. Click the Edit
schedule link to create or edit a monitor schedule.
For more information about working with monitor schedules,
see the section on Schedule
Preferences for Monitoring.
- Monitor Description
-
Enter additional information about this monitor. The Monitor
Description can include HTML tags such as the <BR>
<HR>, and <B> tags to control display format and style.
The description will appear on the Monitor Detail page.
- Report Description
-
Enter an optional description for this monitor that will make it easier to
understand what the monitor does. For example, network traffic or
main server response time. This description will be displayed on
with each bar chart and graph in Management Reports and appended to
the tool-tip displayed when you pass the mouse cursor over the
status icon for this monitor on the monitor detail page.
- Depends On
-
To make the running of this monitor dependent on the status of
another monitor or monitor group, use the drop-down list to select
the monitor on which this monitor is dependent. Select
None to remove any dependency.
- Depends Condition
-
If you choose to make the running of this monitor dependent on the
status of another monitor, select the status condition that the
other monitor or monitor group should have in order for the current
monitor to run normally. The current monitor will be run normally
as long as the monitor on which it depends reports the
condition selected in this option.
- List Order
-
By default, new monitors are listed last on the Monitor Detail
page. You may use this drop-down list to choose a different
placement for this monitor.
- Error if
-
You use this option to customize the conditions under
which the Port Monitor generates an error status message.
You can change this to generate an error based on the length of
the round trip times. Enter a comparison value and use the
comparison operator list to specify an error threshold such as:
>= (greater than or equal to), != (not equal to), or < (less
than).
- Warning if
-
You use this option to customize the conditions under
which the Port Monitor generates a warning status message. By
default, the Port monitor does not have a warning threshold, but
you can set this option to define one.
Enter a comparison value and use the comparison operator list to
specify an error threshold such as: >= (greater than or equal
to), != (not equal to), or < (less than).
- Good if
- SiteScope maintains a good status if the reading returned is 200,
but you can change this to be based upon round-trip time.
|