The Additional SNMP Settings Form
Use the Add Additional SNMP Settings form to define additional SNMP profiles
to which SiteScope can send pages in the event of an error or warning
condition. You must create a SNMP setting profile for each SNMP host to which you want
SiteScope to send pages. Each setting added to the Add Additional SNMP Settings becomes
available in the Send SNMP Trap box in the SNMP Trap Alert set up
form.
Complete the Add Additional SNMP Settings Form as indicated below.
Selection and configuration of the Host, Object ID, and Trap ID is the same as
for the default SNMP setting
on the SNMP Preferences form.
- Setting Name
-
Type in the name for these SNMP settings. For example, if you want
to use these settings for a secondary console, type secondary
settings in the text box. When you add an alert you can
select secondary settings from the list of SNMP settings.
- Disabled
-
Click this button to stop SNMP alerts from being sent using these
settings.
- Send to Host
-
Enter the host name of the machine to which this trap should be
sent. For example, snmp.thiscompany.com. This machine must be
running an SNMP console.
- SNMP Object ID
-
Indicate the SNMP object that is sending the trap. For example
.1.3.6.1.2.1.1 is the "system" object from MIB-II (RFC
1213).
- SNMP Community
-
Enter the SNMP community name used for this trap - usually this is
"public".
- Trap ID:Generic
-
Specify the generic trap type. If the generic trap type is
"enterprise specific", then enter the number that
represents the specific trap type.
When you have completed the form click the Save Changes
button.
|